Online shop for business customers

Track Rehabilitation / Inliner

The trenchless inliner method enables fast and comparatively inexpensive sewer rehabilitation. Particularly in the case of long pipe sections, it quickly becomes apparent that the effort and costs involved in inliner rehabilitation remain within reasonable limits. This is because instead of tearing up the floor and walls, a tube made of robust fabric material (the so-called liner) is impregnated with special resin and then inserted into the pipe. Using water or air pressure, the hose is pressed against the pipe wall from the inside and hardens there. After the curing time, the sewer pipe is permanently sealed again and the sewer rehabilitation is completed after appropriate testing.

If direct bonding to the old pipe is not desired, we recommend the use of a preliner. A preliner is a flexible film tube that is inserted between the liner and the old pipe. The preliner also protects the textile liner from water penetration.

What you should also know
1 From 5
Close filters
 
  •  
  •  
from to
No results were found for the filter!
Calibration Hose Temperature Resistant up to 80°C DN 100 - 400
Content 1 Meter
From €10.07*
Calibration hose - temperature resistant up to 80°C (Water / Steam), DN 100 - 400 mm, orange....
Guiding Rope 100m
€77.00*
Guiding Rope 100m
Sanikom In House Liner SX2 3 mm 90° Bends DN 40 - 300
Content 1 Meter
From €15.40*
Sanikom In House Liner SX2 , thickness 3 mm, for bends up to 90°, available from DN 40 to DN 300...
Calibration Hose Temperature Resistant up to 50°C DN 50 - 200
Content 1 Meter
From €6.29*
Calibration hose - temperature resistant up to 50°C, DN 50 - 200m, purple. Calibration hoses are...
Pressure Gauge D 120 mm
€66.00*
Pressure Gauge D 120 mm
Pressure Regulator 0 - 4 bar
€79.20*
Pressure Regulator 0 - 4 bar
Pre-Liner HPDE 100 µ DN 100 - DN 400
Content 10 Meter (€3.41 * / 1 Meter)
From €34.10*
Sanikom Pre-Liner HPDE in versions from DN 100 - DN 400 , HPDE 100 µ. Seamless pre-liners used to...
Calibration Hose Temperature Resistant up to 80°C DN 100 - 350
Content 1 Meter
From €10.07*
Calibration hose - temperature resistant up to 80°C (Water / Steam), DN 100 - 350 mm, transparent...
Blue Epoxy Systems For In-House and Lateral Systems
Content 16.8 Kilogram (€15.40 * / 1 Kilogram)
From €258.72*
Sanikom epoxy resin bundle for in-house and mainline rehabilitation , hardens very quickly ....
Epoxy Systems For Mainline Liner Low Viscosity
Content 16.8 Kilogram (€14.70 * / 1 Kilogram)
From €246.96*
Epoxy resin system with low viscosity for the main pipe area, consisting of resin and hardener,...
Inversion Drum Sanidrum 400 With 6" Storz
€6,358.00*
Sanidrum 400 Inversion Drum with 6" Storz - low weight (32 kg) inversion drum made of composite...
Inversion Drum Sanidrum 600 With 6" Storz
€7,326.00*
Sanidrum 600 Inversion Drum with 6" Storz - low weight (39 kg) inversion drum made of composite...
1 From 5

Important information about inliner rehabilitation

  • Inliner rehabilitation can also be the best solution for indoor repairs. However, it is not suitable for every pipe as the preliner and liner remain in the pipe and reduce its diameter. The nominal diameter should therefore not be too small. The thickness of the liner used should also be checked and considered accordingly.
  • Pipe rehabilitation using the inliner method should only be carried out by experienced professionals! Compared to short liner rehabilitation, which should also only be carried out by professionals, inliner rehabilitation is more complex. In addition, the use of compressed air to invert the liner and the use of hot water (steam) to cure the liner require the utmost care and expertise.

* All prices are quoted net of the statutory value-added tax and shipping costs and possibly delivery charges, if not otherwise described